Algfail(SVG-fail, algsuurus 750 × 438 pikslit, faili suurus: 34 KB)

Lühikirjeldus

Kirjeldus
English: Diagram of a phase change heat pump.
Note that the arrows in the diagram are meant to indicate the flow of air and coolant; they do not correspond to heat flow, which in the system depicted is (generally) from right to left.
Deutsch: Schema einer Wärmepumpe mit Phasenwechsel.
Allikas Üleslaadija oma töö
Autor Ilmari Karonen
SVG genesis
InfoField
 
The SVG code is valid.
 
See vektorkujutis on valmistatud rakendusega Inkscape.
 
This diagram uses embedded text/digits.

Legend

  1. Condenser coil (hot side heat exchanger, gas cools and liquifies)
  2. Metering Device (liquid expands and cools)
  3. Evaporator coil (cold side heat exchanger, liquid vaporizes and heats up)
  4. Compressor (gas is compressed and heats up)
Red = Gas at high pressure and very high temperature
Pink = Liquid at high pressure and high temperature
Blue = Liquid at low pressure and very low temperature
Light Blue = Gas at low pressure and low temperature

Litsents

Public domain Selle teose autoriõiguste valdajana annan selle teose avalikku omandisse. See kehtib üleilmselt.
Kui see pole mõnes riigis õiguslikult võimalik:
Annan kõigile õiguse seda teost kasutada ükskõik mille jaoks, ilma ühegi tingimuseta, kui seadus neid just ei sea.

Pealdised

Lisa üherealine seletus sellest, mida fail esitab

Selles failis kujutatud üksused

kujutab

Faili ajalugu

Klõpsa kuupäeva ja kellaaega, et näha sel ajahetkel kasutusel olnud failiversiooni.

(uusimad | vanimad) Näita (uuemad 10 | ) (10 | 20 | 50 | 100 | 250 | 500)
Kuupäev/kellaaegPisipiltMõõtmedKasutajaKommentaar
viimane5. aprill 2017, kell 12:22Pisipilt versioonist seisuga 5. aprill 2017, kell 12:22750 × 438 (34 KB)Jahobrcleanup, I hope errors are fixed
13. detsember 2007, kell 11:20Pisipilt versioonist seisuga 13. detsember 2007, kell 11:20750 × 438 (63 KB)No-w-ayReverted to version as of 20:49, 12 December 2005
12. detsember 2007, kell 19:07Pisipilt versioonist seisuga 12. detsember 2007, kell 19:07750 × 438 (51 KB)No-w-ayReverted to version as of 20:27, 12 December 2005
12. detsember 2007, kell 19:06Pisipilt versioonist seisuga 12. detsember 2007, kell 19:06715 × 367 (88 KB)No-w-ayNew version with the arrow in the evaporator coil reversed to show correctly the heat transfer (from outside environment to the inside fluid).
12. detsember 2007, kell 19:03Pisipilt versioonist seisuga 12. detsember 2007, kell 19:03715 × 367 (88 KB)No-w-ayDiagram of a phase change heat pump. Drawn in Inkscape by Ilmari Karonen. New version with the arrow in the evaporator coil reversed to show correctly the heat transfer (from outside environment to the inside fluid).
12. detsember 2005, kell 23:49Pisipilt versioonist seisuga 12. detsember 2005, kell 23:49750 × 438 (63 KB)Ilmari Karonenso close...
12. detsember 2005, kell 23:46Pisipilt versioonist seisuga 12. detsember 2005, kell 23:46750 × 438 (62 KB)Ilmari Karonenkeep trying
12. detsember 2005, kell 23:42Pisipilt versioonist seisuga 12. detsember 2005, kell 23:42750 × 438 (50 KB)Ilmari Karonensigh...
12. detsember 2005, kell 23:38Pisipilt versioonist seisuga 12. detsember 2005, kell 23:38750 × 438 (50 KB)Ilmari Karonengoddammit!
12. detsember 2005, kell 23:35Pisipilt versioonist seisuga 12. detsember 2005, kell 23:35750 × 438 (50 KB)Ilmari Karonendamnit, why can't these things render consistently?
(uusimad | vanimad) Näita (uuemad 10 | ) (10 | 20 | 50 | 100 | 250 | 500)

Seda faili kasutab järgmine lehekülg:

Globaalne failikasutus

Järgmised muud vikid kasutavad seda faili:

Vaata selle faili globaalset kasutust.

Metaandmed